WT-FY24B

WT-FY24B
WT-FY24B

WT-FY24B Mobile Energy Metering & Electrician Practical Skills System (Case-type)

The system utilizes DC power supply below safety voltage levels. The output voltage and current employ low-signal AC to simulate real-world voltage/current amplitudes and power factors. This mobile simulation System can replicate various wiring configurations for 3-phase 3-wire (3P3W) and 3-phase 4-wire (3P4W) energy meters. Despite its compact size, it offers rich functionality, simulating tens of millions of wiring combinations. It is ideal for professional skill training and assessment for personnel in energy metering and power inspection at vocational schools, training centers, and utility departments.

Core Positioning: A medium-sized training system that balances “mobile portability” with “dual-meter collaborative training.” Featuring an aluminum alloy case with a trolley-and-wheel design, it is specifically built for small-to-medium training centers, skill competitions, and certification scenarios.

Product Functions

  • Topology Simulation: Built on a multi-dimensional mathematical model and logic engine for energy meter wiring, enabling full-scenario topology simulation of metering sites.
  • Dynamic Condition Simulation: Accurately reproduces any wiring combination via computer programs, supporting dynamic condition simulation and result analysis for complex field scenarios.
  • Load Characteristic Simulation: Integrated module with built-in standard power factor test points: 0.5L (Inductive), 0.5C (Capacitive), 1.0 (Pure Resistive), 0.8L, and 0.8C. Supports continuous phase angle adjustment from 0° to 360°.
  • Flexible Configurations: Supports tens of millions of combinations across multiple scenarios:
    • HV 3P3W: Accessed via VT (V/V connection) and CT (simplified wiring).
    • HV 3P3W: Accessed via VT (V/V connection) and CT (phase-separated wiring).
    • HV 3P3W: Accessed via VT (Y/Y connection) and CT (simplified wiring).
    • HV 3P3W: Accessed via VT (Y/Y connection) and CT (phase-separated wiring).
    • HV 3P4W: Accessed via VT (Y0/Y0 connection) and CT (simplified wiring).
    • HV 3P4W: Accessed via VT (Y0/Y0 connection) and CT (phase-separated wiring).
    • LV 3P4W: (No VT) Accessed via CT (simplified wiring).
    • LV 3P4W: (No VT) Accessed via CT (phase-separated wiring).
  • One-Key Hotkeys: For 3P3W systems, includes 48 built-in standard wiring combinations accessible via hotkeys for rapid scenario switching and standardized calibration.
  • Examination System: Integrated question bank supporting automated generation, categorized storage, and random retrieval for skill assessment and certification.
  • Multi-Level Protection: Real-time monitoring of voltage/current loops for abnormal states (short circuit, open circuit) with automatic audio-visual alarms.
  • Grounding Fault Simulation: Simulates grounded and ungrounded conditions for Voltage Transformers (VT) and Current Transformers (CT) to analyze the impact on metering accuracy.
  • Professional Reporting: Supports standardized printing of calibration records, test papers, phasor diagrams, wiring topologies, correction factor tables, and retroactive energy compensation reports.
  • Smart Meter Compatibility: Compatible with 3P3W and 3P4W smart energy meters of various specifications.
  • Closed-Loop Error Correction: Integrated Volt-Ampere Phase Meter module for real-time data acquisition and analysis after wiring correction, ensuring a complete “wiring-correction-verification” workflow (Optional).

Product Features

  • Mobile Efficiency: 20-inch aluminum trolley case with wheels and retractable handle. Easily transportable by one person for rapid setup in classrooms or temporary exam sites.
  • Independent Dual-Meter Training: Features two independent meter positions (3P3W + 3P4W) allowing simultaneous, interference-free training for group competitions or “Red vs. Blue” drills.
  • Billion-Level Scenarios: Accurately replicates over a hundred million wiring error combinations involving VTs, CTs, and meter terminals, highly consistent with actual field operations.
  • Global Safety Compliance: Powered by a 12V DC safe power supply (Output: 0–12V, 0–100mA), meeting international electrical safety standards.

Technical Specifications

  • Input Power:AC 220V ,50Hz,(Adapter output 12V DC; customizable for local standards).
  • Output Voltage: 0~12V.
  • Output Current: 0~100mA.
  • Simulated Phase Meter Display: Voltage 0~380V;Current0~5A.
  • Phase Angle: 0–359.9°, adjustment resolution 0.1°.
  • Frequency: 45–65Hz,(continuously adjustable).
  • Dimensions: 460mm (W) × 640mm (D) × 280mm (H).
  • Weight: Approx. 25kg.

Standard Delivery Package

No. Item Specification Quantity
1 Main Unit WT-FY24B Main Unit 1 Set
2 Tablet Computer 8GB+256GB, 12.4-inch, 2.5K High Color Gamut Touch Screen 1 Unit
3 Phase Meter Simulation Type 1 Unit
4 Three-Phase Four-Wire Transformer-Rated Meter Customized per local meter standards (Optional) 1 Unit
5 Three-Phase Three-Wire Transformer-Rated Meter Customized per local meter standards (Optional) 1 Unit
6 Accessories Packing list, Certificate, Manual, Test report, Warranty card 1 Set

Our case studies

Featured case studies

From the blog

Our latest posts

China STATE GRID
CNNP
China huaneng